Brand:AMPXL
Description:4*2*0.50BC+HDPE+PVC
Origin:China Guangdong
Model:500-1
MOQ:100Boxes
FOB:perBoxes40--55USD
Port:Shenzhen any port
Payment Terms:T/T
Supply Time:Day
Packaging Details:305 meter/ box, 2 boxes/ export carton
Product detail:The AMPXL BOX UTP CAT5e cable is the highest-quality twisted pair cable designed for professional data transmission systems inside buildings (structural wiring, LANs).
The AMPXL cable comes from the latest generation of UTP twisted pair cables. Its external diameter has been reduced to 5.0 mm, which considerably facilitates insertion of the cable into ducts and pipes. Special insulation material makes it easier to attach RJ-45 connectors.
Main features of AMPXL UTP cat 5e cable:
highest-quality materials, strict technological discipline confirmed by a 15-year quality guarantee,
parameters far exceeding the requirements for Category 5+ twisted pair cables
preliminary quality control of materials and thorough tests of the final product,
meter markers, deviation less than 0.5%,
solid wires of 0.50 mm diameter (24 AWG),
wire insulation made of homogeneous, colored PE; outer diameter: 0.88 mm; colors: white-green/green, white-orange/orange, white-brown/brown, white-blue/blue,
insulated wires twisted in pairs of 1.8 mm diameter,
pairs twisted together, outer diameter of ca. 4.0 mm,
sheath made of gray/ blue PVC, of 5.0 mm diameter.
The AMPXL UTP cat 5e LAN cable is manufactured in compliance with:
IEC 61156-6, ISO/IEC 11801, ANSI/TIA/EIA-568-B, yd/t1019-2001 standards.
The AMPXL UTP cat 5e cable can be used in a wide temperature range: -20°C...+70°C, and installed between 0°C and +50°C. The minimum bending radius factor (radius to diameter ratio) is 8.
Specifications
Name | AMPXL Cat UTP 5e |
Code | 500 |
Structure | |
Wires | solid copper conductors Ø 0.50 mm (24 AWG) |
Wire insulation | HDPE |
Sheath | PVC (gray/ blue) |
Outer diameter [mm] | 5.0 ±0.3 |
Copper content [kg/km] | 14.9 |
Weight [kg/km] | 28.5 |
Electrical parameters | |
Impedance [Ω] | 100 ±15 |
Capacitance of any transmission path at 1kHz [nF/km] | 50 ±1 |
Nominal Velocity of Propagation (NVP) [%] | 67 |
Resistance of any transmission path [Ω/km] | ≤ 188 |
Asymmetry in capacitance of transmission paths to the ground [pF/km] | ≤ 1600 |
Insulation resistance [MΩ/km] | > 500 |
Installation and operation | |
Operating temperature range [°C] | -20...+70 |
Operating humidity range [%] | 0...100 |
Installation temperature range [°C] | 0...+50 |
Minimum bending radius [radius to diameter ratio] | >8 |
Cable | Pair | Wire | Wire resistance [Ω/km] | Resistance asymmetry [%] |
UTP cat. 5e | 1 | a | 92,726 | 0,35 |
b | 93,054 | |||
2 | a | 94,662 | 0,34 | |
b | 94,982 | |||
3 | a | 96,228 | 0,55 | |
b | 96,755 | |||
4 | a | 96,107 | 0,39 | |
b | 95,733 | |||
Required | - | - | <150 | ≤3,0 |
Cable | Pair | Effective capacitance [nF/km] | Capacitance asymmetry [pF/km] |
UTP cat. 5e | 1 | 47,35 | 77 |
2 | 44,87 | 132 | |
3 | 45,71 | 36 | |
4 | 46,70 | 5 | |
Required | - | - | ≤1600 |
Cable | Pair | Wire | Insulation resistance [MΩ/km] |
UTP cat. 5e | 1 | a | 8,8·104 |
b | 1,2·105 | ||
2 | a | 9,0·104 | |
b | 1,6·105 | ||
3 | a | 8,1·104 | |
b | 2,0·105 | ||
4 | a | 7,5·104 | |
b | 1,1·105 | ||
Required | - | - | ≥50 |
Test method | Test voltage VAC | |
Applied (passed) | Required | |
Voltage applied between connected in parallel all a wires and all b wires | 1000 | 1000 |
Cable | Pair | Effective attenuation [dB] |
UTP cat. 5e | 1 | 22,9 |
2 | 22,8 | |
3 | 21,5 | |
4 | 21,2 | |
Required | - | ≤24,9 |
Cable | Pair to pair | NEXT [dB] |
UTP cat. 5e | 1 - 2 | 43,5 |
1 - 3 | 47,9 | |
1 - 4 | 45,3 | |
2 - 3 | 44,9 | |
2 - 4 | 47,8 | |
3 - 4 | 41,4 | |
Required | - | ≥34,0 |
Cable | Pair | Return loss [dB] |
UTP cat. 5e | 1 | 20,8 |
2 | 21,2 | |
3 | 20,9 | |
4 | 19,9 | |
Required | - | ≥19,4 |
Cable | Pair | PS-NEXT [dB] |
UTP cat. 5e | 1 | 36,94 |
2 | 33,93 | |
3 | 33,63 | |
4 | 35,44 | |
Required | - | ≥31,0 |