      AN9651TH (F)(Three Phase/single phase7 in1)

      Ground Bond Test

      Empty Load Output Voltage

      <12V

      Output Current Setting Range

      AC3A~30A 50Hz/60Hz,1A/step

      Output Current Setting Accuracy

      ±(2% of setting+0.2A)

      Upper Limit of Resistance

      3A≤output current≤10A, 10~600mΩ; 10A

      Ground Bond Resolution/ Measurement Range/ Accuracy

      1mΩ, 10~600mΩ, ±(2% of reading +2mΩ)

      Compensation Resistance Measurement Range/Accuracy

      0~200mΩ 1mΩ

      Test Time Setting Range

      0.5~999.9s 0.1s/step

      Insulation Resistance Test

      Rated Output Load/Current

      1VA (1000V/1mA) 1mA

      Output Voltage Range/Adjustable

      DC:500V/1000V <1% (Empty load to full load)

      Output Voltage Ripple

      Pure resistance load, 1000V/1mA, <3%

      Insulation Resistance Range

      1.0~2000MΩ

      Insulation Resistance Lower Limit Setting Range/ Resolution

      1.0~99.9 MΩ, 0.1MΩ/step, 100~2000 MΩ 1 MΩ/step

      Insulation Resistance Accuracy

      1~200 MΩ: ±(2% of reading+2counts) , 200~2000 MΩ: ±(5% of reading+5counts)

      Ramp-up Time Range/Resolution

      0.1~999.9s 0.1s

      Delay Judgment Time

      0.3~10.0s (Count from ramp-up )

      Test Time Setting Range

      0.5~999.9s 0.1s/step

      AC Hipot Test

      Rated Output Load

      500VA (AC:5000V/100mA)

      Output Voltage Range /Frequency/Adjustable Rate

      500~5000V, 50Hz/60Hz, <2%(Empty load to full load)

      Output Voltage Setting Range/Accuracy

      Cold state AC:500~5000V, Hot state AC:500~2500V, 5V/step, ±(2.5% of setting+5V)

      Leakage Current Preset Alarm

      Upper limit: 0.10~99.99mA; Lower limit: 0.00~99.99mA , 0.01mA/step

      Compensation Current Setting Range/ Resolution

      0.00 ~5.00mA, 0.01mA

      Output Initial Voltage Range

      (0%~99%) of test voltage, from 0V to initial voltage need 200ms

      Leakage Current Measurement Range/Resolution/Accuracy

      0.10~99.99 mA, 0.01mA, ±(2% of reading +2counts)

      Test Time/Ramp-Up/Ramp-Down

      0.5~999.9s, 0.1~999.9s, 0.0~999.9s(After test pass)

      DC Hipot Test

      Rated Output Load

      60VA (AC:6000V/10mA)

      Output Voltage Range /Frequency/Adjustable Rate

      500~6000V, <2%(Empty load to full load)

      Output Voltage Setting Range/Accuracy

      Cold state AC:500~6000V, Hot state AC:500~2500V, 5V/step, ±(2.5% of setting+5V)

      Leakage Current Preset Alarm

      Upper limit: 50~9999μA; Lower limit: 0~9999μA , 1μA

      Compensation Current Setting Range/ Resolution

      0 ~5000μA, 1μA

      Output Initial Voltage Range

      (0~99%) of test voltage, from 0V to initial voltage need 200ms

      Leakage Current Measurement Range/Resolution/Accuracy

      50~9999μA , 1μA, ±(2% of reading +2counts)

      Test Time/Ramp-Up/Ramp-Down

      0.5~999.9s, 0.1~999.9s, 0.3~10.0s(Count from ramp-up)

      Leakage Current Test

      Output Voltage Range

      1.06 times of input voltage (output by isolated transformer)

      Leakage Current Range/Resolution

      Upper limit: 50~9999μA 1μA

      Compensation Current Setting Range/ Resolution

      0~500μA 1μA

      Test Time Range/Resolution

      1.0 ~999.9s 0.1s

      Leakage Type

      dynamic, static

      Three Phase Dynamic Mode

      A mode: ABC-AB-BC-CA (standard)
      B mode: ABC-AB-ABC-BC-ABC-CA (customized)

      Output Voltage Measurement Range/Accuracy

      AC 50~500.0V 0.1V, ±(0.5% of reading+2counts)

      Leakage Current Measurement Range/Accuracy

      50~9999μA 1μA 
      DC~10kHz: ±(2% of reading+5counts) 10kHz~1MHz: ±(5% of reading+5counts)

      Leakage Current Accuracy

      50.0~2000μA is ±(5% of reading);2000μA or above is ±(2.5% of reading)

      Leakage Power

      6kVA ,isolated transformer capacity is designed according to the rated voltage 220V

      Time Setting Range

      1~300s

      Measurement Mode

      dynamic, static

      Power Test

      Output Voltage Range

      1.00 times of input voltage (output by isolated transformer)

      Power Setting Range/Resolution

      Upper limit, Single phase:20~6000W Three phase:60~20000W
      Lower limit, Single phase:0~6000W Three phase:0~20000W 1W/step

      Test Time Range/Resolution

      0.5 ~999.9s 0.1s

      Voltage Measurement Range and Accuracy

      AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts)

      Current Measurement Range and Accuracy

      AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts)

      Active Power Measurement Range and Accuracy

      20.0~999.9W; 1.000~9.999kW; 10.00~20.00kW 
      45~65Hz: ±(0.5% of reading +2counts)

      Power Factor Range and Accuracy

      0.100~1.000, ±(2% of reading +2counts)

      Low Voltage Start Test

      Output Voltage Range

      0.85 times of input voltage (output by isolated transformer)

      Test Time Range/Resolution

      0.5 ~999.9s 0.1s

      Current Setting Range/Resolution

      Upper limit: 0.30 ~30.00A Lower limit: 0.00 ~30.00A0.01A

      Voltage Measurement Range and Accuracy

      AC:50.0V~500.0V, 45~65Hz: ±(0.5% of reading +2counts)

      Current Measurement Range and Accuracy

      AC:0.30~30.00A, 45~65Hz: ±(0.5% of reading +2counts)

      Display Mode

      10.4 Inch, 640×480, TFT LCD display

      Isolated Transformer Capacity

      Three Phase:20kVA, Single Phase: 6kVA

      Over Current Protection

      Power, Start, Leakage Current, Phase Current35A, over 5s protection

      DUT Type Setting

      Single Phase, Three phase Three line, Three phase Four line

      Grounding Mode

      Load Grounding, Load Floating

      DUT Error Processing

      Voice and light alarm

      Outer Alarm Light

      Red alarm light

      PLC Output Interface

      Each test function have one

      Interface Function

      RS232, Outer Printer, Remote

      Optional Interface

      RS485, GPIB, Internet Card, Inner Printer

      Remote control Interface

      Foot Pedal, three-color alarm light(on-off signal output, PRINTER, 97 COM interface, Mini-Printer function optional)

      Test Group

      15 groups, 8 steps / group

      Buzzer Alarm Voice

      Can turn on ,Can cut